Linkable LED strip lights plug end to end, so a long row in a warehouse aisle, garage or back room can run from one power feed instead of one feed per fixture. The limit is how much load one chain can carry, and each manufacturer sets that limit on its spec sheet. This guide walks through planning a continuous run with two JEE strip families we list, using only the numbers on the JEE ST02 spec sheet and the JEE ST05 spec sheet.
How linking works
On the ST02, the sheet says to plug the male or female connector from the previous light into the female or male connector of the next light. The ST05 sheet calls its version seamless electronic linking and lists wiring on both ends and in the middle. Both sheets show a linkable plate, sold separately, that joins two fixtures on the back so the row stays straight.
Run limits from the spec sheets
JEE ST02
The ST02 sheet sets a maximum of 450W on one chain, with a maximum of 10 of the 4 ft fixtures or 5 of the 8 ft fixtures, and an 80 ft maximum daisy chain.
| ST02 size | Wattage settings | Max fixtures per chain |
|---|---|---|
| 4 ft | 20, 30 or 45W | 10 |
| 8 ft | 70, 80 or 90W | 5 |
JEE ST05 (4 ft)
The ST05 sheet works from the wire, not a flat count. It bases the allowable load on 18 AWG wire with a 6A current limit: 720W at 120V and 1662W at 277V. It divides that load by the fixture wattage for a theoretical maximum, then gives a lower conservative rated count:
| Wattage setting | Conservative count at 120V | Conservative count at 277V |
|---|---|---|
| 30W | 18 | 40 |
| 40W | 13 | 30 |
| 50W | 11 | 25 |
| 60W | 9 | 20 |
The ST05 has a fifth setting of 68W, which the sheet's chain table does not list. Ask us for the count before you plan a chain at that setting. Plan from the conservative column, and have the installing electrician confirm the branch circuit.
Planning a run
- Measure the row: count 4 ft and 8 ft fixtures to fill the length.
- Set the wattage: pick each fixture's wattage setting first, since the chain limit depends on it. See selectable wattage and CCT.
- Split long rows: when the total passes the sheet limit, start a new chain with its own feed.
- Order the parts: add linkable plates or cables for each joint. See the accessory below.
- Controls: both families are 0 to 10V dimmable per their sheets. See 0 to 10V dimming explained.
- Sensors and emergency: the ST02 comes in sensor base and emergency battery versions. See occupancy sensors and emergency battery backup fixtures.
Linkable strips and parts we list
| Product | From the spec sheet | Price |
|---|---|---|
| JEE ST02 4 ft, sensor base | 20, 30 or 45W; 3500K to 6500K selectable; up to 10 per chain (sheet) | $22.75 |
| JEE ST02 8 ft, sensor base | 70, 80 or 90W; up to 5 per chain (same sheet) | $41.75 |
| JEE ST02 4 ft, emergency battery | 20, 30 or 45W; up to 10 per chain (same sheet) | $67.75 |
| JEE ST02 8 ft, emergency battery | 70, 80 or 90W; up to 5 per chain (same sheet) | $86.75 |
| JEE ST05 4 ft | 30, 40, 50, 60 or 68W; 3500K, 4000K or 5000K selectable; chain counts above (sheet) | $28.50 |
| JEE linkable cables, 4 ft strips | Accessory listed for the 4 ft ST, ST02, ST03 and ST05 strips | $2.00 |
Check each product page and spec sheet for that fixture's UL, ETL and DLC listings. For more strip and shop light options, see the strip lights collection and our commercial LED shop lights guide.
Common questions
How many linkable LED strips can go on one chain?
It depends on the fixture and its spec sheet. The JEE ST02 sheet sets 450W maximum, with up to 10 of the 4 ft or 5 of the 8 ft fixtures. The JEE ST05 sheet gives conservative counts by wattage and voltage, from 9 to 18 fixtures at 120V and 20 to 40 at 277V.
Why does the ST05 allow more fixtures at 277V?
The sheet bases the chain on 18 AWG wire with a 6A current limit, which is 720W at 120V and 1662W at 277V.
Do I need extra parts to link strips?
Both sheets show a linkable plate, sold separately, that joins two fixtures on the back. We also list JEE linkable cables for the 4 ft ST, ST02, ST03 and ST05 strips.
Does the wattage setting change the chain limit?
Yes. The limit is total load, so lower settings allow more fixtures on one chain, as the ST05 table shows.
Can sensor and emergency versions be part of a run?
The ST02 comes in sensor base and emergency battery versions. Confirm the wiring for those versions on the sheet, and ask us before mixing versions on one chain.
Send your row layout for a job quote. Questions? Contact us or call (845) 681 2684.
Ready to price the job?
Build your order and submit it for a freight quote. We ship from the manufacturer's warehouse to all 50 states, and nothing is charged until you approve the total.