Lighting by Application

Spec by space

Lighting by application

Nobody walks in wanting a 150 watt UFO high bay. They walk in with a building. Find the space, get the fixture type, the light level to aim for and the mistake that costs a callback.

Light levels below are the general target measured at the working surface. They are starting points for pricing a job, not a substitute for a photometric layout on a large building.

Industrial and storage

Warehouse and distribution

10 TO 30 FC

High bays above fifteen feet, strip fixtures below that. The mistake: round UFO fixtures over racked aisles. A UFO throws a circle, an aisle is a long rectangle, so most of the output lands on top of the rack instead of down where the picker is. Run linear high bays along the aisles.

Manufacturing and assembly

30 TO 75 FC

High bays for the general layer, task lighting on top where the work is fine. The mistake: ignoring the ambient temperature rating. An uncooled plant in August is nowhere near the 25 degree lab condition the lumen numbers were measured at, and a driver rated to 40 or 50 degrees simply lasts longer.

Cold storage and freezers

20 TO 30 FC

Vapor tight, gasketed, rated for low ambient. The mistake: assuming any wet location fixture works. LEDs like the cold but drivers and gaskets do not always, and door cycling drives condensation. Check the low end of the temperature rating, not just the high end.

Auto shop and service bays

50 TO 75 FC

Linear high bays or strip fixtures over the bays, with high colour rendering so paint and wiring colours read true. The mistake: mounting too high. In a bay you want light down into the engine bay and under the lift, not a wash across the ceiling.

Offices, schools and healthcare

Open plan office

30 TO 40 FC

2x2 or 2x4 in the grid, 4000K, dimmable. The mistake: flat panels in a room full of monitors. A large uniformly bright surface overhead shows up as screen reflections and a harshness nobody can name. Center baskets recess the source and fix it.

Classrooms

30 TO 50 FC

2x2 center baskets, 4000K, dimming for projector use. The mistake: forgetting egress. Emergency and exit lighting is a separate requirement with its own inspection, and it is cheaper to spec it now than to add it after the walkthrough.

Clinics and exam rooms

50 TO 100 FC

High CRI at the table, softer general lighting around it. The mistake: speccing on lumens alone. In a room where somebody is judging skin tone, colour rendering matters more than raw output. Look for CRI 90 and above.

Corridors and stairwells

10 TO 20 FC

Wraparounds or slim panels, usually on occupancy sensors. The mistake: running them at full output around the clock. A corridor that nobody is in for eight hours a night is the easiest energy saving in the building, and stairwells have their own egress rules.

Retail and hospitality

Retail sales floor

30 TO 75 FC

General layer plus accent on displays. The mistake: lighting everything evenly. Contrast is what pulls the eye to a display, so feature areas want two to five times the general level rather than the whole floor going brighter.

Gyms and rec centers

30 TO 50 FC

High bays, wide beam, with impact rated lenses. The mistake: chasing the average and ignoring uniformity. On a court you want a tight 2:1 average to minimum, which is why these layouts come out denser than a warehouse of the same size.

Exterior and parking

Parking lots

0.5 TO 3 FC AVERAGE

Pole mounted area lights, distribution matched to where the poles sit. The mistake: quoting on average foot candles. A lot averaging 1.5 can be 6 under each pole and 0.2 between them, and the eye adapts to the bright spot and goes blind to the dark one.

Parking garages

5 FC, 10 TO 20 AT RAMPS

Vapor tight or canopy, wet location, impact rated. The mistake: speccing damp location because there is a roof. Cars carry water in, floors get washed and wind drives rain into the perimeter bays. Garages are wet locations, and the fixtures run twenty four hours.

Building exterior and security

5 TO 10 FC AT ENTRIES

Wall packs on the building, floods for facades and yards. The mistake: buying on wattage. Mounting height decides the fixture, and a growing number of jurisdictions now require full cutoff and cap colour temperature outdoors.

Fuel canopies and car washes

20 TO 30 FC

Canopy fixtures under cover, IP66 vapor tight in the wash tunnel. The mistake: treating an IP rating as corrosion protection. It is not. A wash tunnel and anywhere near salt water need a housing finish rated for it, so ask for salt spray data.

Walkways and campus paths

0.5 TO 2 FC

Bollards along paths, area lights on the wider runs. The mistake: over lighting. On a path, evenness matters far more than brightness, and a bright pool every forty feet reads worse than a lower, continuous level.

Loading docks

20 TO 30 FC

High bays or strips inside, wall packs outside, dock lights at the doors. The mistake: lighting the dock and forgetting the apron. Trucks back into the dark, and the approach usually needs its own fixture.

Most of what we carry is wattage and colour temperature selectable. That means you can lock the layout in now and set the output after you have walked the space with a meter, without reordering. How selectable fixtures work.

Tell us the building, not the part number

Square footage, ceiling height and what happens in the space. We will come back with the fixture, the count and a price you can drop straight into your bid.

Send us the building